Product Details:

Place of Origin: China
Brand Name: Supmeter
Certification: CE
Model Number: dCX-61-BST106-B68[U]

Payment & Shipping Terms:

Minimum Order Quantity: 1pc
Price: negotiation
Packaging Details: carton
Delivery Time: 3workdays
Payment Terms: Western Union, T/T
Supply Ability: 10000pcs/month
Get Best Price Contact Now

Detail Information

Power Supply: DC24v Material: Steel
Verfication Accuracy: 0.02% Verification Accuracy: III
Max. Connection Number Of Loadcell: 4 Loadcells (350Ω) Communication Port: COM1:RS232; COM2:RS485
High Light:

programmable load cell controller

,

load cell indicator

Product Description

High Accuracy Load Cell Display And Controller 400Hz Sampling Frequency

 

Technical Specification

Executing Standard

  • CMC GB/T 7724-2008PRC National Standard.
  • OMIL R76: 2006International Recommendation.
  • Accuracy Grade: III.
  • Verification Accuracy: 0.03%.
  • Static Weighing Accuracy: 0.2%~0.5%.
  • Batching Accuracy: 0.2%~0.5%.

Display

  • 6+8 Red LED digital tubes for English character and digit display.
  • Weight Display Range: -99,999~+999,999.
  • Scale Capacity: Setting Range 1~999,999.
  • Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
  • Display Resolution: 1/100,000.
  • Weight Unit: Optional kg, t, g, none.
  • Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
  • Display Refreshing Time: Setting Range 0.01~1.00s.

Kaypad

  • Model Panel-mounting: 4-key English keypad.
  • Model Explosion-proof: 6-key English keypad.
  • Menu&Shortcut mode operation with key tone.

Loadcell Interface

  • Excitation Voltage/Max. Current: DC9V/120mA [4-350Ω loadcells].
  • Signal Input Range: 0~22.5mV.
  • Output Sensitivity of Loadcell: 1.0~2.5mV/V.
  • 24-bit ∑-△ADC with internal resolution 1/1,000,000.
  • Sampling Frequency: 400Hz.
  • Special anti-vibration digital filtering algorithm.
  • Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
  • Gain Drift: ±5ppm/℃.
  • Non-linearity: 0.005%FS

Switch&Analog Signal Interface

  • 6 Normally Open Switch Inputs [DI].
  • 8 Normally Open Transistor Switch Outputs [DO]: DC24V, 250mA.
  • 1 Optional&Definable Analog Signal Output [AO]: 4~20mA, Non-linearity: 0.05%FS.

Digital Communication Interface

  • COM1: RS232.
  • COM2: RS485.
  • Connectable: Host IPC/PLC and LED Remote Display.

Operating Specification

 Operating Voltage

  • Model Panel-mounting: DC24V±20%.
  • Model Explosion-proof: AC110~240V, 50/60Hz.

  Max. Power Consumption: 5W.

 

Outline Size and Weight

  • Model Explosion-proof: 256×290×166mm [W×H×D].
  • Model Explosion-proof: Approx. 9.2kg.

Operating Temperature: -25℃ to +45℃.

Storage Temperature: -30℃ to +60℃.

Relative Humidity: Max. 85%RH.

Application Environment of Model Explosion-proof

  • Explosion gas environment: Zone 1&2.
  • Classes of explosion gas mixture: IIA, IIB.
  • Temperature grades of explosion gas mixture: T1~T6.
  • Ex-mark: Ex d IIB T6 Gb.

Protection Level

Front Panel of Model Panel-mounting: IP65.

Model Explosion-proof: IP65.

   

 

Keypad Operation

      If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.

 

Menu Operation
Key Name Description
【MENU】

Enter Main Menu.

Exit.

【ENT】 Enter / Save / Alarm Acknowledge.
【◄】

Cursor shifts left.

Display the previous option.

【►】

Cursor shifts left.

Display the next option.

【▲】

Display the next interface or option.

Digit input: +1 ( 0~9 loop).

【▼】

Display the previous interface or option.

Digit input: -1 ( 0~9 loop).

Quick Operation

【MENU】

【Ñ】

*

  • Key-locking.
  • Key-unlocking.

【◄】

(【SET】)

M1~M4 Target Values setting.

【◄】

【ZERO】

【→0←】

*

  • [-ZEro-]: Zero Calibration with Power-down Protection and Clearing Tare Weight.
  • [≡ZEro≡] Zero Fine Adjustment without Power-down Protection and without Clearing Tare Weight.
  • The controller will switch to Gross Weight display.

【▲】

【TARE】

【→T←】

*

  • [≡tArE≡]: Manual Tare without Power-down Protection.
  • [-PStr-]: Preset Tare Weight with Power-down Protection.
  • [-rStr-]: Clear Tare Weight with Power-down Protection.
  • The controller will switch to Net Weight display.

【ENT】

【G/N】

Gross Weight / Net Weight display switch.
【ENT】

Pause State:

  • [Cont]: Recover Running.
  • [StoP]: Stop.

*: Keep the key pressed for 2 seconds.

 

 

Model Explosion-proof Operation Interface:

High Accuracy Load Cell Display And Controller 400Hz Sampling Frequency 0

 

Installation:

High Accuracy Load Cell Display And Controller 400Hz Sampling Frequency 1

 

System Diagram for M1~M4 Ration Batching System:

High Accuracy Load Cell Display And Controller 400Hz Sampling Frequency 2

 

 

 

Want to Know more details about this product
I am interested in High Accuracy Load Cell Display And Controller 400Hz Sampling Frequency could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.